RO system is raw water through precision filter, granular activated carbon filters.activated carbon filters, compression, and then through the pump pressure, theuse of reverse osmosis membrane pore size 1/10000um make a higher concentration of water into low concentration of water, while the industrial pollutants,heavy metals, bacteria, viruses and other impurities in the water mixed with a l-arge number of full isolation, to achieve the required physical and chemical in-dicators for drinking and hygiene standards, outputs to clean pure water is thebest choice of body replenish water quality.
1000 L/H single-stage RO reverse osmosis equipment Main parameters
Water inlet requirements
Tap water may meet the water quality requirements of the "Sanitary Drinking Water Standards" (GB5749-85).
The inlet water quality requirements of the membrane section: SDL; ≤5, turbidity ≤1, iron content ≤0.1mg/, free chlorine ≤0.1mg/l.
Water quality
The effluent water quality and sanitation comply with the Ministry of Health's request
Water production
1000L/H, 25℃ water temperature
Recovery rate
60%-65%
water temperature
5℃~45℃
power
2.5KW
Suitable power supply
AC380V 50HZ
Net weight of equipment
≈450KG
Appearance size
1650*600*1700mm (Length x Width x Height)
Interface size
Water inlet G≥32 ,Concentrated water outlet>25, Water purification outlet≥25
1000 L/H single-stage RO reverse osmosis equipment system flow chart
Municipal tap water → Raw water booster pump → Quartz sand filter → activated carbon filter → Resin softener → Precision filter → High pressure pump → Reverse osmosis system → Equipment water outlet
application
Treatment of drinking water for daily use; Deep purification of tap water, well water, ancsurface water; Process water, food and medicineThe treatment of product water, clarifi.cation, separation, purification, and concentration of various materials; Industrial wast-ewater and sewage treatment department Management, reclaimed water reuse, ROpre-treatment